Saluki’s SER series EMI test receiver can used to to assemble the test system of electrical lighting or similar products.
Fig.1 Main EMC test standards for lighting products
Scope of Applications:
• All lighting equipment used for lighting that has the basic function of generating and/or distributing light and intended to be connected to a low-voltage power supply or operated with batteries
• One of the main functions is the lighting part of the lighting multifunctional equipment
• Independent auxiliary equipment dedicated to lighting equipment
• Ultraviolet and infrared radiation equipment
• Neon advertising signs
• Road or floodlights intended to be used outdoors
• Transportation lighting (installed on cars and trains)
Fig.2 EMC test
Lighting Equipment Working Conditions
• Ambient temperature: 15 to 25℃
• Working voltage: within ±2% of the rated voltage
• Light source aging: 2 hours for incandescent lamp, 100 hours for fluorescent lamp and other lamps
• Stabilization time: 5 minuts for incandescent lamp, 15 minuts for fluorescent lamp, 30 minuts for others
Fig.3 EMC test equipments
Conducted Disturbance Test
Test Site: Electromagnetic shielding room
Test Equipments: EMI test receiver + LISN + Limiter
Fig.4 Conducted disturbance test
Radiated Disturbance Test (3D loop antenna)
Test Site: Electromagnetic shielding room
Test Equipments: EMI test receiver + 3D loop antenna
Frequency Range: 9 kHz to 30 MHz
Fig.5 Radiated disturbance test
Radiated Disturbance Test (CDN method)
Test Site: Electromagnetic shielding room
Test Equipments: EMI test receiver + CDN
Frequency Range: 30 MHz to 300 MHz
Fig.6 Radiated disturbance test (CDN)
EMC Analysis Software
Fig.7 EMC analysis software (for Windows 7/8/10)
• Built-in lighting standard
• Conducted test
• CDN test
• Correction factor
• Manual/automatic
• Real-time frequency standard
• Test data editing
• Excessive data browsing