S3532 Series Spectrum Analyzer (up to 7.5GHz)

Saluki S3532 is a bench top spectrum analyzer designed for R&D, manufacture, maintenance and education. S3532 has excellent performance and multi-functions. Frequency reaches 7.5GHz and DANL is <-150dBm (<-161dbm typ.). S3532 integrated most used functions are standard, save the troubles for customer lost themselves in the complex configuration guide. Pre-amplifier, AM/FM demodulation, Interference analysis, limit line, OBW, ACPR etc, all these functions are provided as a standard part. Optional tracking source and CW source extend the ability of S3532. Engineers can easily use it as a network analyzer.


Key Features
  • Frequency range: 9kHz - 7.5GHz
  • DANL <-150dBm, <-161dBm typ
  • Max 3GHz tracking source and CW source
  • Audio analysis
  • Standard preamplifier/waterfall function/Limit line function
  • SCPI supported
Applications
  • Education
  • RF system test
  • RF component manufacture / maintenance
  • Telecommunication equipment manufacture / Maintenance



Saluki S3532 is a bench top spectrum analyzer designed for R&D, manufacture, maintenance and education. S3532 has excellent performance and multi-functions. Frequency reaches 7.5GHz and DANL is <-150dBm (<-161dbm typ.). S3532 integrated most used functions are standard, save the troubles for customer lost themselves in the complex configuration guide. Pre-amplifier, AM/FM demodulation, Interference analysis, limit line, OBW, ACPR etc, all these functions are provided as a standard part. Optional tracking source and CW source extend the ability of S3532. Engineers can easily use it as a network analyzer.






Technical Specifications

 

S3532A

S3532B

Specification

Frequency range

9 kHz - 3.6 GHz

9kHz - 7.5GHz

Resolution

1 Hz

1Hz

RBW Range

1 Hz - 500 kHz, 1 MHz, 3 MHz

1Hz - 500kHz, 1MHz, 3MHz

VBW Range

10 Hz - 3 MHz

10Hz - 3MHz

DANL (CF = 1GHz, RBW=1Hz)

<-135 dBm Preamp off
<-155 dBm Preamp on

<-133dBm Preamp off
<-148dBm Preamp on

SSB Phase Noise (CF=500 MHz, RBW=1kHz)

Carrier offset 30 kHz

 -90  dBc/Hz

 -80 dBc/Hz

Carrier offset 100 kHz

 -100  dBc/Hz

 -90 dBc/Hz

Carrier offset 1 MHz

 -115 dBc/Hz

 -110 dBc/Hz

Maximum safe input level

Average continuous power

+27 dBm

 +23 dBm

DC voltage

50 Vdc maximum

50 Vdc maximum

Input attenuator range

0 - 39 dB,Steps of 3 dB

0 - 30dB,Steps of 1 dB

TOI

>30 MHz

+13 dBm

 +15 dBm

SHI

+30 dBm

 +40 dBm

Input related spurious

<-60 dBc

<-60 dBc

Inherent residual response

<-85 dBm

<-85 dBm

Test Port

Type -N female(50Ω)

Communication Port

USB, LAN


General Information

Display

8.4 inch TFT LCD

Dimensions

390(H)×182(W)×230(D)mm

Weight

6.5 kg

Power

100 V - 240 V, 60 Hz AC



Software
S3532A-01 Tracking signal source1.5/3.2GHz
S3532A-02 Tracking Source + Normal Signal Source
S3532A-03 FFT 1Hz RBW
S3532A-04 Audio demodulation & measurement
S3532B-01 Tracking signal source1.5/3.2GHz
S3532B-02 FFT 1Hz RBW
S3532B-03 Audio demodulation & measurement

Hardware
S3532A-07 EMI  The near field probe
S3532B-06 EMI  The near field probe
No videos available for this product at present.